PRODUCT FEATURES
- High gloss, single component moisture cure aromatic polyurethane topcoat
- Remarkable hardness and impact resistance
- Very good chemical and solvent resistance
- Outstanding adhesion
- Exceptional steel tank lining or protective coating for interior concret
- Single component product avoids mixing errors
- Easy to apply with any traditional painting equipment
- Very good curing times
- Can be applied in damp or humid conditions
Suggested Uses
- Steel tank lining applications
- Salt spreaders, hopper cars or any steel structure to be lined
- Interior concrete floors
Technical Data
| Coating type |
Single component
moisture cure urethane |
| Colour |
Amber |
| Packaging |
3.78 L (1 US gallon) |
| Mixing Ratio |
Single component |
| Gloss |
90% |
| Flashpoint (ASTM D93) |
-4º C (25º F) |
| Thinner |
GS UC 500S |
| Pot life |
4 to 6 hours |
| Shelf life |
1 years |
| Density (ASTM D 1475) |
1.00 kg / L +/- 0.05 |
| Weight |
8.32 +/- 0.11 lb / US gal. |
| Volatile organic compound
(VOC) |
3.9 lb / US gal. (464 g/L) |
| Temperature resistance |
100º C (212º F) in continuous service |
| Solids (ASTM D1644) |
| By weight |
53 +/- 2% |
| By volume |
46 +/- 2% |
| Theoretical
spreading rate |
18 sq.m / l at 25 microns dry
735 sq.ft. / US gal at 1 mil |
| Recommended film thickness |
50 microns dry
(2.0 dry mils) |
| Application methods |
Conventional air spray, brush, roller, airless and HVLP |
Surface Preparation
The surface preparation recommended for AMBER-SHIELD™ MC
4509 is to include removal of all oil, grease, dirt, dust, mill scale, rust,
paint, corrosion product and other foreign matters.
For concrete: Surface must be clean and free of any contaminants.
For proper surface preparation recommendations, please consult a
reputable floor applicator.
Mixing and Thinning
AMBER-SHIELD™ MC-4509 is a one component product supplied in
1 US gallon container.
Thinning is not normally required or desired ; however, at lower
temperatures, small amounts (10% or less) of Glass Shield GS UC
500S thinner can be added depending on local VOC and air quality
regulations. Any solvent addition should be made after the one
component product is thoroughly stirred.
The pot life or the "working pot" is up to 6 hours. After the paint
is stirred and poured, immediately seal the original can. Higher
temperatures or humidity will shorten the pot life. Do not apply over
water or frozen surfaces.
Application Conditions
Industry standards are for the substrate temperatures to be above
10º C of the dew point. Condensation due to substrate temperatures
below the dew point can cause flash rusting on prepared steel and
interfere with proper adhesion to the substrate.
Special application techniques may be required above or below
normal application conditions.
| Condition |
Material |
Surface |
Ambient |
Humidity |
| Normal |
60 - 85º F
(16 - 29º C) |
65 - 85º F
(18 - 29º C) |
60 - 90º F
(16 - 32º C) |
0 - 65% |
| Minimum |
50º F (10º C) |
23º F (5º C) |
23º F (5º C) |
0% |
| Maximum |
90º F (32º C) |
100º F (35.5º C) |
100º F (35.5º C) |
85% |
DISCLAIMER: All information is given in good faith. Since conditions of use are beyond the manufacturer's
controls, all information contained herein is without warranty, implied or otherwise. All technical data and
specifications are subject to change. Please consult with your Glass Shield representative for more detailed
coating recommendations. Revised 08-01-2007
Typical Sequence (First class finish)
Application
AMBER-SHIELD™ MC-4509 can be applied by brush, roller or spray.
For spray equipment adjustments, please contact one of our sales
representative or technicians.
Curing times given at 23ºC (73ºF) and 40% relative humidity. Higher
or lower temperatures will affect drying times. Dry film thickness
over 3 mils DFT may cause bubbling.
Airless & Air Spray
| Manufacturer |
Graco |
| Pump |
30 : 1 |
| Fluid hose |
3/8" x 100' max |
| Tip size |
* |
| PSI |
2400 PSI min. |
| Manufacturer |
Devilbiss |
SATA |
| Spray gun |
HET |
K3 RP |
| Fluid tip |
1.4-1.6 ff |
1.4-1.6 |
| Air cap |
#410 / 414 |
|
| Fluid line |
3/8" |
3/8" |
| Pressure pot |
15 - 25 psi |
40 psi |
| Atomizing air |
50 - 60 psi |
36 psi |
* Refer to Kremlin chart for specific uses or consult
Glass Shield technical services
Curing Schedule
Ventilate the substrate for 2 hours after application. Curing times
are based on a 2.0-3.0 mil (50-75 micron) dry film thickness. Higher
film thickness, insufficient ventilation or cooler temperatures will
require longer cure times and could result in solvent entrapment and
premature failure of the film. Maximum recoat time is 5 days without
special surface preparation. If you desire a longer recoat window,
an additive can be added. Consult a Glass Shield representative for
further information. If the maximum recoat time has been exceeded,
the surface must be sanded or prepared with a brush off blast SSPCSP-
7 prior to the application of additional coats. AMBER-SHIELD™
MC-4509 applied below 40ºF (4º C) may temporarily soften for
several hours, after temperatures rise to 60ºF (16º C). This is a normal
condition and will not influence performance.
| Dry to touch |
2 hours |
| To recoat |
2-4 hours (sanding required after 10 hours) |
| Hard |
4-6 hours |
| Full cure |
7 days |