PRODUCTS TECHNICAL DATA SHEET|TOPCOATS


Amber-Shield MC 4509

AMBER-CLEAR TOP COAT

MOISTURE CURE URETHANE

PRODUCT FEATURES

  • High gloss, single component moisture cure aromatic polyurethane topcoat
  • Remarkable hardness and impact resistance
  • Very good chemical and solvent resistance
  • Outstanding adhesion
  • Exceptional steel tank lining or protective coating for interior concret
  • Single component product avoids mixing errors
  • Easy to apply with any traditional painting equipment
  • Very good curing times
  • Can be applied in damp or humid conditions

Suggested Uses

  • Steel tank lining applications
  • Salt spreaders, hopper cars or any steel structure to be lined
  • Interior concrete floors

Technical Data

Coating type Single component moisture cure urethane
Colour Amber
Packaging 3.78 L (1 US gallon)
Mixing Ratio Single component
Gloss 90%
Flashpoint (ASTM D93) -4º C (25º F)
Thinner GS UC 500S
Pot life 4 to 6 hours
Shelf life 1 years
Density (ASTM D 1475) 1.00 kg / L +/- 0.05
Weight 8.32 +/- 0.11 lb / US gal.
Volatile organic compound

(VOC)

3.9 lb / US gal. (464 g/L)

Temperature resistance 100º C (212º F) in continuous service
Solids (ASTM D1644)
By weight 53 +/- 2%
By volume 46 +/- 2%
Theoretical

spreading rate

18 sq.m / l at 25 microns dry

735 sq.ft. / US gal at 1 mil

Recommended film thickness 50 microns dry

(2.0 dry mils)

Application methods Conventional air spray, brush, roller, airless and HVLP

Surface Preparation

The surface preparation recommended for AMBER-SHIELD™ MC 4509 is to include removal of all oil, grease, dirt, dust, mill scale, rust, paint, corrosion product and other foreign matters.

For concrete: Surface must be clean and free of any contaminants. For proper surface preparation recommendations, please consult a reputable floor applicator.

Mixing and Thinning

AMBER-SHIELD™ MC-4509 is a one component product supplied in 1 US gallon container.

Thinning is not normally required or desired ; however, at lower temperatures, small amounts (10% or less) of Glass Shield GS UC 500S thinner can be added depending on local VOC and air quality regulations. Any solvent addition should be made after the one component product is thoroughly stirred.

The pot life or the "working pot" is up to 6 hours. After the paint is stirred and poured, immediately seal the original can. Higher temperatures or humidity will shorten the pot life. Do not apply over water or frozen surfaces.

Application Conditions

Industry standards are for the substrate temperatures to be above 10º C of the dew point. Condensation due to substrate temperatures below the dew point can cause flash rusting on prepared steel and interfere with proper adhesion to the substrate.

Special application techniques may be required above or below normal application conditions.

Condition Material Surface Ambient Humidity
Normal

60 - 85º F

(16 - 29º C)

65 - 85º F

(18 - 29º C)

60 - 90º F

(16 - 32º C)

0 - 65%
Minimum 50º F (10º C) 23º F (5º C) 23º F (5º C) 0%
Maximum 90º F (32º C) 100º F (35.5º C) 100º F (35.5º C) 85%

DISCLAIMER: All information is given in good faith. Since conditions of use are beyond the manufacturer's controls, all information contained herein is without warranty, implied or otherwise. All technical data and specifications are subject to change. Please consult with your Glass Shield representative for more detailed coating recommendations. Revised 08-01-2007

Typical Sequence (First class finish)

Application

AMBER-SHIELD™ MC-4509 can be applied by brush, roller or spray. For spray equipment adjustments, please contact one of our sales representative or technicians.

Curing times given at 23ºC (73ºF) and 40% relative humidity. Higher or lower temperatures will affect drying times. Dry film thickness over 3 mils DFT may cause bubbling.

Airless & Air Spray

Manufacturer Graco
Pump 30 : 1
Fluid hose 3/8" x 100' max
Tip size *
PSI 2400 PSI min.

Manufacturer Devilbiss SATA
Spray gun HET K3 RP
Fluid tip 1.4-1.6 ff 1.4-1.6
Air cap #410 / 414
Fluid line 3/8" 3/8"
Pressure pot 15 - 25 psi 40 psi
Atomizing air 50 - 60 psi 36 psi

* Refer to Kremlin chart for specific uses or consult Glass Shield technical services

Curing Schedule

Ventilate the substrate for 2 hours after application. Curing times are based on a 2.0-3.0 mil (50-75 micron) dry film thickness. Higher film thickness, insufficient ventilation or cooler temperatures will require longer cure times and could result in solvent entrapment and premature failure of the film. Maximum recoat time is 5 days without special surface preparation. If you desire a longer recoat window, an additive can be added. Consult a Glass Shield representative for further information. If the maximum recoat time has been exceeded, the surface must be sanded or prepared with a brush off blast SSPCSP- 7 prior to the application of additional coats. AMBER-SHIELD™ MC-4509 applied below 40ºF (4º C) may temporarily soften for several hours, after temperatures rise to 60ºF (16º C). This is a normal condition and will not influence performance.

Dry to touch 2 hours
To recoat 2-4 hours

(sanding required after 10 hours)

Hard 4-6 hours
Full cure 7 days